Overhead 2-Remotes Fault Detection System

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-10-06 07:14
Browse the number: 251
inquiry
Company Profile
 
 
Product details
Introduction of on - line monitoring system for line 1. Single system basic configuration

Overhead communication fault indicator         Several Groups (3 / Group)

Overhead communication terminal                  Several Units (each communication

                                                                         terminal may equipped with 1-3

                                                                         Groups of fault indicators)

Asymmetrical current source                         Several Units (optional)

Information processing terminal                     1 Set

Computer (Central Station)                           1 Set

Central station software(regional                   1 Set

       master station is optional)

Installation tools                                       Assigned according to standard

                                                                           (1 Set/100pcs)

2. System structure

    Line fault on-line monitoring system is a set of intelligent fault management system with remote distribution monitoring, centralized management and instant notification. It makes the existing fault detection technology progressed, which combines the line fault detection and communication transmission technology. By sending the information to the master station and completing the topology fault location, display and alarm notification at the master station, the fault location and query of the line become much faster. As shown below, the system consists of communication fault indicator, signal source, communication terminal, working master station,etc. And the working master station includes signal receiving terminal, master software, computers and mobile phones.


 

The communication fault indicator is mounted on the line, which is mainly composed of modules of fault detection, current sampling, triggering alarm, wireless radio frequency communication, power and other functional modules. The main function is to detect the line information of power transmission, power outage, earthing, short circuit, etc., and transfer them to the communication terminal through short-range radio frequency communication. Three fault indicators are one group, which can be installed and removed while line is in charge condition using special installation tools.

The fault indicator is usually in the power-saving sleep state; when the line state changes, the detection function module will be activated and it will analyze, calculate and process the collected information  by the SCM, to determine whether the line occurs state changes such as power transmission, power outage, short circuit and earthing; If the changes are determined,the alarm function module would be activated and the information would be transferred securely and accurately through the radio frequency transmitting module. After receiving the information, the communication terminal returns a "received" signal, and the fault indicator returns to the sleep state after receiving this signal.

The communication fault indicator adopts a double power supply mode using line powering as its main power, lithium batteries and super capacitors as a backup power supply. The device uses line powering supply when it is in normal condition, and charge for the backup power supply;when the line power is out, or the power supply is not sufficient, the super capacitor start to supply power; when the super capacitor power is depleted, the backup battery  starts to supply power and it can supply more than 8 years.

    The Communication terminal is mainly composed of the MCU processing unit, GSM / GPRS remote communication, short-range radio frequency communication and photovoltaic power supply processing and other functional modules. Main function: two-way radio communication with the fault indicator to complete the interaction of information, including the configuration of indicator parameters, control and receiving the fault information of indicators; complete communication with the master station through the means of GSM / GPRS and so on, which includes receiving the command of master station, control and reporting various operating information and detected information of the indicator and terminal upwards automatically. The terminal should be installed on the pole which is less than 100 meters from the communication fault indicator , using hoop to fix directly.

Each communication terminal can be equipped with multiple sets of communication fault indicators in the range of 100 meters.

Communication terminal adopts a dual power supply mode, using solar energy as the main power, rechargeable batteries and super capacitors as a backup power supply. In a clear day, the solar panels can provide sufficient energy, while the back-up power can get charged; When at night and cloudy day, the communication terminal is powered by backup power supply.

The signal source is installed at the neutral point of the earthing transformer of substation (connected to the bus / outlet when there is no neutral point). Signal injection method to detect earth fault requires the signal source going into automatic, short-term dynamic resistive load, generating a special zero sequence current signal (less than 50A) between the substation and site earthing point, and resulting in encoded signal current superimposed on the load current through the coding control of the resistance in case of earthing fault occurred in the system. The earth fault indicator installed at the point of substation outlet and branching of line will detect this current signal and indicate it.

The primary part of signal source device, which is applied in neutral point earthing system by arc suppression coil, is connected to the neutral point of earthing transformer. And the primary part of signal source, which is applied in Neutral point unearthing system,  is connected to the three-phase bus / outlet. When the earth fault occurs on the line, the substation signal source determines the earth phase automatically by detecting the bus zero sequence voltage and the three-phase voltage. When the earth fault continues for a period of time, the signal source would go into the AC contactor of the corresponding phase and starts to send the current signal sequence, there’s no signal get through in non-faulted outlet and non-faulted phases. After the signal source sending out the signal, the fault indicator installed on faulty phase of the faulty line detects the current signal sequence from the signal source, then flop, flashes and transmits the action signal to the master station through the communication terminal.

The information processing terminal performs the following functions: communicating with the communication terminal and performing protocol conversion, extracting the information from the communication terminal or forwarding the background information to the communication terminal; communicating with the background, forwarding the information to the communication terminal or forwarding the information from the communication terminal to the background; When the master station completes the fault judgment, and needs to send the fault information through SMS for alarm, it will send the information to the set mobile phone through the mobile communication network, so that the relevant staff can deal with the line fault in time.

Computer specific configuration requirements:

Server: Intel Pentium CPU 2.6G or above, 4G memory above, hard drive 160G above, at least one serial interface (COM1 port) and USB port;

Operating System: 2003, 2008 Standard Edition or Enterprise Edition;

Monitor;

Keyboard / mouse / optical drive / multihole socket;

The software of mast